Skip to content
in cooperation withCIC Berlin

ELECTRONICS · MAKER LAB

Build your idea.
See how it works.

Power, measure, connect: turn a circuit into a prototype you can test. Discover which instruments work together and how to prepare your project.

What do you want to find out? ↓
SIGNALMEASUREMENTPROTOTYPE
Electronics at the Maker Lab
Electronics at the Maker Lab

01 / PROJECT PATHS

What do you want to find out?

Four project paths connect the equipment with a concrete result.

01Test a sensor prototypeFrom a first circuit to a measurement you can explain.

Combine these tools
Bench supply + DSO-1084E; add FG-1251 or DG4102 to simulate input signals.

  1. Define the supply, expected current and signal you want to test. Start with a low-voltage circuit agreed with the team.
  2. Wire with power off. Check polarity, leads and the common ground reference; set supply voltage and current limit.
  3. Enable the checked circuit. Compare supply and sensor signals on the oscilloscope; change one variable at a time.
  4. Record the circuit version, settings and trace. Disable outputs before altering the wiring.

Your result
A trace and a brief finding: which sensor change produces which signal?

If something goes wrong: Unexpected current, strong heating or an unstable supply: disable the output and check the circuit with the team.

02Understand a filter or amplifierApply a known signal and see what changes.

Combine these tools
DG4102 or FG-1251 + DSO-1084E; add a bench supply for active circuits.

  1. Define the question: amplification, attenuation, delay or distortion? Set an allowed level and frequency range.
  2. Check load setting, amplitude, offset and grounding. Compare the set input signal with the actual applied voltage.
  3. Observe input and output on two oscilloscope channels. Change frequency in steps and record levels.
  4. Compare the measurements with your expectation. If spectral content matters, plan a separate DSA815 measurement with the team.

Your result
A short measurement series shows where the circuit performs as intended.

If something goes wrong: Clipping or an unexpected offset: disable the output and check signal level, load and supply.

03From breadboard to circuit boardTurn a working experiment into a durable assembly.

Combine these tools
Weller soldering station + suitable fume extraction; bench supply and oscilloscope for functional checks.

  1. Transfer the verified circuit into a wiring or assembly plan. Agree on components, solder and a suitable tip.
  2. Prepare the instructed workstation with a heat-resistant rest and effective extraction. Solder only unpowered assemblies.
  3. Inspect joints and possible bridges. Prepare hot-air work for the specific component and board; a temperature value is not a universal recipe.
  4. Test the finished assembly with limited current. Record connections and function, let hot tools cool and leave the bench tidy.

Your result
A labelled, checked assembly for your prototype.

If something goes wrong: Poor extraction, damaged leads or uncertain component compatibility: pause work and involve the team.

04Clean suitable small partsMaterial and cleaning liquid determine the process.

Combine these tools
VEVOR ultrasonic cleaner; suitable basket and approved cleaning liquid.

  1. Identify the material, coating and contamination. Check part and liquid compatibility with the team.
  2. Check the exact model and its manual. Prepare liquid level, basket, temperature and time for the agreed process.
  3. Clean only suitable parts and inspect the result. Do not experiment with batteries or unchecked electronics; do not use flammable liquids.
  4. Remove, rinse and dry as agreed. Dispose of the liquid according to its contents.

Your result
A clean, dry part without visible surface damage.

If something goes wrong: Unknown coating, unsuitable liquid or visible changes: do not continue the process.

02 / LAB EQUIPMENT

Start with the right setup.

Choose a task. Device details explain strengths, limits, photographs and manufacturer references.

01Power your circuitsThree bench supplies for different power requirements.
RIGOL DP832

MAKR-0022

RIGOL DP832

3 outputs · 2× 0–30 V / 0–3 A · 1× 0–5 V / 0–3 A

Supplies prototypes with adjustable DC voltage. Multiple outputs suit circuits requiring different supply rails.

Accessories & your project path

What to consider: Set the current limit and check polarity before enabling an output. Do not combine outputs without a verified setup.

Prepare for your projectSuitable leads, insulated clips and a circuit diagram. Map outputs and shared references in advance.

Power a sensor separately
  1. Record supply requirements for the sensor and readout circuit.
  2. Connect with outputs off and set appropriate current limits.
  3. Enable supplies deliberately and compare current draw with the expected value.

Your resultA checked supply arrangement for the prototype.

EA-PS 2384-05 B

MAKR-0026

EA-PS 2384-05 B

3 outputs · 2× up to 84 V / 5 A, max. 160 W each · 3–6 V / 12 W

Flexible power for more demanding test setups. Both main outputs offer voltage and current combinations within their power limit.

Accessories & your project path

What to consider: 84 V and 5 A are not available simultaneously. Higher voltages require a suitably qualified and approved setup.

Prepare for your projectSuitable leads and load; respect each output’s power limit. Use only the voltage range covered by your induction.

Check a prototype’s power needs
  1. Establish permitted voltage, expected current and power.
  2. Set voltage and current limit with the output disabled.
  3. Power the load under supervision and record current in the intended operating states.

Your resultA basis for choosing the eventual power supply.

VOLTCRAFT LSP-1403

MAKR-0027

VOLTCRAFT LSP-1403

1 output · ranges 16 V / 5 A, 27 V / 3 A, 36 V / 2.2 A

Compact bench supply for a single power rail. Select the operating range to match the circuit.

Accessories & your project path

What to consider: Three selectable ranges, not three outputs. Disable the output before rewiring.

Prepare for your projectInsulated leads, suitable clips and a low-voltage circuit.

Power a new board for the first time
  1. Inspect assembly and polarity with the board unpowered.
  2. Choose the appropriate range; set voltage and a suitably low current limit.
  3. Enable output and watch current; switch off for unexpected limiting or heating.

Your resultA controlled first startup with recorded current draw.

02Generate test signalsTwo generators provide defined input signals.
RIGOL DG4102

MAKR-0020

RIGOL DG4102

2 channels · up to 100 MHz · 500 MSa/s

Generate defined test signals for filters, amplifiers and sensor circuits. Two channels support comparative experiments.

Accessories & your project path

What to consider: 100 MHz is the maximum sine frequency; other waveform limits differ.

Prepare for your projectBNC leads, suitable terminations and an oscilloscope. Establish the test circuit’s input limits first.

Compare two signals
  1. Define two waveforms for the test circuit.
  2. Check outputs on the oscilloscope first, including load/termination settings.
  3. Apply each signal in turn and record the circuit response.

Your resultComparable responses to two known input signals.

VOLTCRAFT FG-1251

MAKR-0021

VOLTCRAFT FG-1251

2 channels · up to 25 MHz · 125 MSa/s

Sine, square and arbitrary waveforms for circuit experiments and comparative measurements.

Accessories & your project path

What to consider: Check amplitude, offset and output load together; the wrong load setting changes the actual signal level.

Prepare for your projectBNC lead, suitable adapters and an oscilloscope; a low-voltage test circuit.

Test a filter systematically
  1. Define the filter, expected frequency range and permitted input.
  2. Check a sine signal on the oscilloscope, then apply it to the filter.
  3. Compare input and output at several frequencies and record a table.

Your resultA repeatable set of measurements showing the filter response.

03Make signals visibleTime-domain waveforms on a scope, frequency content on the spectrum analyser.
VOLTCRAFT AO-610

MAKR-0023

VOLTCRAFT AO-610

Analogue oscilloscope · 1 channel · 10 MHz

Shows periodic voltage waveforms directly. Useful for learning timebase, triggering and waveform interpretation.

Accessories & your project path

What to consider: No digital storage. Check the probe, ground reference and input limits before connection.

Prepare for your projectA suitable, correctly compensated probe and a safe low-voltage setup.

Make an oscillation visible
  1. Identify the measurement point and permitted ground reference with the circuit off.
  2. Set up the probe and display the signal using a suitable timebase and trigger.
  3. Read amplitude and period and compare with the expected values.

Your resultA clear view of the signal waveform.

VOLTCRAFT DSO-1084E

MAKR-0024

VOLTCRAFT DSO-1084E

Digital oscilloscope · 4 channels · 80 MHz · up to 1 GSa/s

Compare several signals in time, such as supply voltage, a sensor signal and a switching output. Useful for fault finding and timing analysis.

Accessories & your project path

What to consider: The E variant has no built-in function generator. The maximum sample rate is not available in every channel configuration.

Prepare for your projectUp to four suitable probes; signal labels and an agreed reference scheme.

Compare a circuit’s startup signals
  1. Choose supply, enable and response as measurement points.
  2. Connect probes safely and trigger acquisition on the startup event.
  3. Compare timing and sequence; save the screen image with the settings.

Your resultA recorded sequence instead of a guessed fault cause.

RIGOL DSA815

MAKR-0025

RIGOL DSA815

Spectrum analyser · 9 kHz–1.5 GHz

Shows the frequency content of a signal. Inspect spectral components and harmonics within the permitted input range.

Accessories & your project path

What to consider: The range ends at 1.5 GHz; 2.4 GHz Wi-Fi is outside it. Check the permitted input level and suitable RF accessories before connecting. A measurement does not replace EMC certification.

Prepare for your projectSuitable 50 Ω RF cable; attenuation and a DC block where needed. Plan input protection with the team.

Identify a signal’s frequency components
  1. Establish source frequency and maximum level; choose a range below 1.5 GHz.
  2. Connect with suitable attenuation and locate the fundamental and other lines.
  3. Record frequencies, levels and measurement settings.

Your resultA spectrum that can be compared meaningfully later.

04Assemble & cleanSoldering, hot air, fume extraction and ultrasound.
Weller · soldering & hot air

MAKR-0011 / MAKR-0012

Weller · soldering & hot air

Soldering station · hot-air station

Connect cables and circuit boards; rework suitable components with hot air. The soldering station and hot-air station support different tasks.

Accessories & your project path

What to consider: Choose a suitable tip or hot-air nozzle and temperature for the component. Work on an unpowered board with appropriate solder fume extraction.

Prepare for your projectSuitable soldering tip or hot-air nozzle, solder, compatible flux, holder, tweezers and fume extraction.

Assemble a circuit board cleanly
  1. Sort parts by value and polarity; secure the board and position extraction.
  2. Solder using the inducted process, accounting for heat-sensitive parts.
  3. Inspect for bridges under magnification and check electrically before power-up.

Your resultAn inspected assembly ready for commissioning.

TOOLCRAFT · solder fume extractor

MAKR-0030

TOOLCRAFT · solder fume extractor

Adjustable bench fan with filter holder

Captures solder fumes at the work area when a suitable filter is fitted and the intake is correctly positioned.

Accessories & your project path

What to consider: Check the installed filter, its condition and the correct position at the soldering bench. The airflow needs to capture the solder fumes.

Prepare for your projectThe correct intact filter and a stable position close to the solder joint.

Prepare the soldering workspace
  1. Check the filter and unobstructed airflow before work.
  2. Position extraction to capture fumes away from the breathing zone.
  3. Observe capture while soldering and reposition if fumes miss the inlet.

Your resultA soldering setup with effective local fume capture.

VEVOR · ultrasonic cleaner

MAKR-0031

VEVOR · ultrasonic cleaner

Digital Pro · heating and timer

Cleans suitable small parts using ultrasound. Match the part, cleaning liquid and temperature.

Accessories & your project path

What to consider: The part and cleaning liquid must be suitable for ultrasound. Do not use flammable liquids. Do not clean batteries or populated circuit boards without an explicit suitability check.

Prepare for your projectSuitable basket, a compatible non-flammable cleaning medium, and rinsing/drying space.

Clean a compatible part
  1. Check material, coating and contamination compatibility with the team.
  2. Clean the part in the basket using a suitable medium and approved programme.
  3. Rinse and dry as specified, then inspect surface and function.

Your resultA cleaned part without surface damage.

Cookie Consent Banner by Real Cookie Banner